Automated Initial Positioning
Source file: automated-initial-positioning.htm
The Automated Initial Positioning tool enables you to register unregistered scans against a reference scan. This tool produces a reasonably good fit for a first attempt. Once positioned the registration should be completed using Global Registration.
Note: The reference scan must be one that has already been registered.
The Automated Initial Positioning tool requires scans to be level, or nearly level.
- 
                                                
View the reference and unregistered scans

 in a view window. - 
                                                
On the Position and Filter tab, go to the Register group. From the Automated Positioning drop-down list select
 Automated Initial Positioning.
                                                 - 
                                                
Select the unregistered scans in the project explorer and drag them into the Data to register section of the panel, or click the corresponding
 button. - 
                                                
Select the reference scan in the project explorer and drag it into the Fixed reference data section of the panel, or click the corresponding
 button. - 
                                                
Click OK or Apply to start the registration process.
 - 
                                                
Once registration has completed, visually inspect the scans to ensure they are positioned correctly.
 - 
                                                
Proceed with global registration.
 
Tip: If the scans do not position correctly try increasing the Sampling level.
Note: The scans will be assembled with the lowest quality alignments last. Therefore, you can deregister the last scans if necessary, and try registering again for a better result. See To Origin.
| 
                                                                 
                                                                          | 
                                                        
| 
                                                                 An initial group of unregistered scans (left) automatically aligned (right).  | 
                                                        
Pit scans can also be aligned automatically.
| 
                                                                 
                                                                          | 
                                                            
                                                                 
                                                                          | 
                                                        
| 
                                                                 Zoomed in detail of minor misalignment of edges of scans (left). Global registration used to fine-tune alignment of these edges (right).  | 
                                                        |